2. To view a specific type of events only, select the desired event type in the 'Filter event class' field.
3. The log is refreshed automatically at a regular interval of five seconds. To avoid any new events'
interruption during data browsing, you can suspend the automatic update by clicking
.
To restore automatic update, click
. Those new events that have not been listed yet
due to suspension will be displayed in the log now.
4. To go to other pages of the log, click the pagination bar at the bottom of the page.
When there are more than 5 pages and the page numbers listed does not show the desired one, click
to have the bar show the next or previous five page numbers, if available.
5. If wanted, you can resort the list by clicking the desired column header. See
Sorting a List
(on page 94).
To clear the local log:
1. Click
on the top-right corner.
2. Click Clear Log on the confirmation message.
Updating the Legrand PDU Firmware
Firmware files are available on the Legrand PDU section of Raritan website's
Support page
When performing the firmware upgrade, the Legrand PDU keeps each outlet's power status unchanged so
no server operation is interrupted. During and after the firmware upgrade, outlets that have been powered on
prior to the firmware upgrade remain powered ON and outlets that have been powered off remain powered
OFF.
You must be the administrator or a user with the Firmware Update permission to update the Legrand PDU
firmware.
Before starting the upgrade, read the release notes downloaded from the Legrand PDU section of Raritan
website's
Support page
the upgrade, contact Legrand Technical Support BEFORE upgrading.
Note that firmware upgrade via iOS mobile devices, such as iPad, requires the use of iCloud Drive or a file
manager app.
Warning: Do NOT perform the firmware upgrade over a wireless network connection.
Firmware upgrade restriction:
Intermediate firmware required for upgrades from "pre-3.3.0" to 3.5.0 or later:
If your Legrand PDU is running any firmware version older than 3.3.0, such as 3.2.30, an intermediate
firmware is required for the upgrade to 3.5.0 or later. Follow the sequence below:
a. Upgrade to an intermediate firmware first, which is either
3.3.x
or
3.4.x
.
b. Then upgrade from the intermediate firmware to 3.5.0 or later.
To update the firmware:
1. Choose Maintenance > Update Firmware.
2. Click
to select an appropriate firmware file.