Maintenance and Troubleshooting
3-2
D960R3
User’s Manual Probot
3.2
Maintenance
Maintenance refers to a variety of activities that should be performed on a
routine basis to optimize performance of the system. Many routine maintenance
activities can be readily performed by the user.
In some cases (e.g. replacement of critical components), we recommend that a
factory trained service engineer should be called to perform the operation. This
will ensure optimal long term performance and maximum uptime. LC Packings
provides a broad range of service support activities to ensure that the Probot
Micro Fraction Collector is functioning in a suitable manner. These activities can
be customized to meet the specific needs of the customer. For further
information, please contact your local LC Packings office or representative.
TABLE 3-1
Recommended Maintenance Schedule
Frequency
Operation
Before operating, check for any air bubbles in
the fluidic lines and degas the wash solvent.
Check that there are no leaks of the fluidics
connections.
Check that salts are not deposited by the
fluidics joints or the needle.
Every Day
When using buffer solutions, flush the system
thoroughly after use with a solvent that does
not contain buffers/salts.
Every 3 months
Inspect the condition of all tubing (cracks, nicks,
cuts, clogging).
Check:
Rotary valve
Syringe
Every 6 months
Replacing the Syringe/Syringe tip
Every year
Inspection, cleaning and lubrication of all
spindles (
contact LC Packings
).
Note: The frequency of the various activities described above is a good starting
point. As the user gains experience with the system, it will be found that some
activities can be done less frequently and other need to be done more frequently.
The frequency is dependent on a number of factors including the nature of the
sample and the mobile phase.
Содержание Probot 161403
Страница 1: ...D960R3 Probot TM Micro Fraction Collector User s Manual P N 161403 www lcpackings com ...
Страница 6: ...Table of Contents vi D960R3 User s Manual Probot This page intentionally left blank ...
Страница 10: ...Instructions for Returning Instruments x D960R3 User s Manual Probot This page intentionally left blank ...
Страница 14: ...CE Declaration xiv D960R3 User s Manual Probot This page intentionally left blank ...
Страница 68: ...Installation and Getting Started 2 48 D960R3 User s Manual Probot This page intentionally left blank ...
Страница 102: ...Appendix C C 6 D960R3 User s Manual Probot This page intentionally left blank ...
Страница 112: ...Appendix D D 10 D960R3 User s Manual Probot This page intentionally left blank ...