POWER CORE User Manual
Version: V6.0.0/5
225/459
14. Snapshots System
When nothing is assigned, or the
Enable
box unchecked (see below), the SAVE and
ERASE functions are always available to the operator.
To protect the functions, assign an input control signal which must be True before SAVE
and ERASE become available.
Enable
To activate the
Snap/XL Unlock
control signal, the
Enable
checkbox must be ticked.
The following control outputs appear under “Logic -> Definition -> Parameter Snapshot” in the 'Tree Selection'
window:
Snapx.set
Active when data is stored to the internal snapshot memory. This can be used to signal
to the operator which memories contain settings and which memories are empty.
Snapx.load
This output is pulsed when the snapshot is loaded.
Src Clipboard.set
Active when data is stored to the internal clipboard.
Glb Snap loaded pulse
This output is pulsed when a
Full
snapshot is loaded.
Src Snap loaded pulse
This output is pulsed when a
Src
snapshot is loaded.