POWER CORE User Manual
Version: V6.0.0/5
451/459
22. Appendices
22.8.4 Function Calls
ParamLoopBack
Test Function. Entered values are Looped Back.
Arguments
Type
allowed
Boolean Par.
B
0 / 1
Integer Par.
I
Int
Real Par.
R
Real
String Par.
U
String
Results
Boolean Res.
B
Integer Res.
I
Real Res.
R
String Res.
U
RampMotorFader
Move a Motor Fader within an entered time
to a defined gain.
Arguments
Type
allowed
Source Name
U
existing Sources /
Sums
Gain[dB]
R
-999 to +9
bounded to -191 to +9
Time[s]
R
0 to 10 ( <0.5 = at once)
Results
Result
I
0 Success
1 Incorrect number of parameters
2 Incorrect datatype
3 Input value out of range
4 Source / Sum not found
5
Source / Sum not assigned
6
Combination of values not allowed
(level difference to small / time to large)
SetPFLState
Set a Sources PFL State.
Arguments
Type
allowed
Source Name
U
existing Sources /
Sums
Status
B
0 / 1
Results
Result
I
0 Success
1 Incorrect number of parameters
2 Incorrect datatype
4 Source / Sum not found
5 Source / Sum not assigned