POWER CORE User Manual
Version: V6.0.0/5
212/459
13. Control Surface Configuration
13.7
System -> Definition -> Parameter = Settings
This branch of the ‘Tree Definition’ defines several global settings:
Parameter
Settings – reference name for the element.
Pan/Bal first
This setting defines the default function of the fader strip’s rotary encoder.
When there is no check in the box, the encoder controls GAIN/MIC settings first. The
operator must then tap down on the control to access PAN/BAL.
Check the box if you wish to reverse the priority and control PAN/BAL first.
Sort by LCD Text
When checked, sources within the source list are sorted by their
Display name
. If
unchecked, the sources are sorted by their
Reference name
. The Display and Reference
names are defined in
NTSC
When checked, Delay times set in the Delay module are calculated using NTSC frames.
Unchecked, the system uses PAL frames.
DMS Integration Mode
This setting defines the time constant for all PPM meters within VisTool. The options are|:
Ultrafast, Fast, Normal or Slow.
Correction Key-LED
Sets an offset for the LED brightness of console keys.
Correction Display
Sets an offset for the OLED brightness.
Disable Sensor
Assigns a control input which will disable the ambient light sensor(s).
Assign the TRUE.Out control output from a
gate to disable the sensor. Or, assign an
MF Key to provide operators with an enable/disable button.
Gain Reset Off
If an input is used as a matrix input and as an input to a source:
Check this box so that the source gain is unaffected if the matrix input is disconnected.
Uncheck the box and the source gain is reset to 0dB IF the matrix input disconnects.
Disable SysMenu
Assigns a control input to disable the
SYS
button on the Central Module. This prevents
operator access to the system options.