POWER CORE User Manual
Version: V6.0.0/5
155/459
11. Routing Matrix
11.2.6 Logic -> RAVENNA Stream Control
This element can be used to configure redundancy for specific RAVENNA inputs.
Primary and backup streams are specified such that if the primary stream is lost or becomes unknown, then the
backup stream will be connected.
For example, if the
Main Stream Name
(MSTR:Stream01) is lost, then within 30 seconds the
Backup Stream
Name
(BKUP:Stream02) will be subscribed. In addition, you can use the
Auto Connect
control signal to ensure
that the
Main Stream
(or
Backup Stream
) is always subscribed.
RAVENNA Stream Control
Reference name for the element.
Input (RAV Core Out)
Enter the input that will be used to subscribe to the streams from the network.
Main Stream Name
Enter the name of the Primary or Main stream exactly as it appears in the network.
Backup Stream Name
Enter the name of the Backup or Alternate stream exactly as it appears in the network.
Stream Connect Timeout in
seconds
Enter a value from 1 to 300.
Alarm Logging Enabled
Enable whether these connections shall be logged via the Alarm Log Server.
Auto Connect
Use this input to ensure that no other undefined streams may be subscribed to this Input.
Any attempt to subscribe to a different stream will cause the
Main Stream
to be
subscribed instead.
Force Main Stream
Connect
Forces the Main stream to be connected.
Force Backup Stream
Connect
Forces the Backup stream to be connected.