POWER CORE User Manual
Version: V6.0.0/5
333/459
18. Configuring Custom Logical Behaviour
Transferring a Macro set
You can transfer any of your macro sets to any system configured within the
Units
branch of the
Macro Editor
.
Macro definitions are transferred via TCP/IP. They are then stored on the control system and are loaded whenever
the system powers on.
In systems with a redundant Master Board, then the macro definitions must be transferred to both Master
Boards.
You can transfer a new macro set without restarting the system. This allows you to modify macros while the
system is running online.
First make sure that your
Macro Editor
PC is connected and communicating with the system you wish to
transfer to. Then make sure that you have transferred the system configuration that supports the Macro setup.
1.
Select the macro set you wish to transfer, and click the
Set Default
button.
2.
Select the unit you wish to transfer to, and check the IP Address.
3.
To start the transfer, either click on the
Transfer
button from the Toolbar, or right-click and select
Transfer
:
A confirmation pop-up automatically appears showing the name of the macroset and unit you will transfer to:
5.
Click on
OK
to proceed.
Your PC will now connect to the system and transfer the macro data.
All 32 macros within the macro set are transferred; you cannot transfer a subset.