21. Trouble-shooting
21.3
IP Networking Issues
21.3.1 What is my system's IP address?
The IP address of POWER CORE is displayed on the front of the unit, once the system is powered and booted.
Turn the rotary control to step through the display pages:
21.3.2 The network connection to my remote device is not working
1.
Try a PING command from your device (if it is a PC).
If you do not receive an answer then proceed as follows:
2.
Is POWER CORE connected to the mains supply?
If not, connect and power on the system.
3.
Try restarting the system with a
4.
Is there a network connection between the remote device and the Lawo control system?
Check your
. If the system and your device are connected via a network switch, then try bypassing
this and use a direct connection from the ETHERNET 1 port, remembering to use a crossed Network cable for
this connection.
5.
Is the IP Address assigned to your device's Network Interface Card set to the correct address range and
subnet mask?
Change the IP settings on your remote device accordingly.