ML62Q1000 Series User's Manual
Chapter 25 Flash Memory
FEUL62Q1000
25-22
25.4.3 Communication Command
3-byte commands are used to make the communication in the ISP function.
Table 25-7 shows the ISP mode commands.
Table 25-7 ISP Mode Command List
Command
Fist byte
Second byte
Third byte
Initial
setting
Initial setting command transmission (1)
0x1A
0x08
0x00
Initial setting command transmission (2)
0x1A
0x00
0x00
Initial setting command transmission (3)
0xC0
0x01
0x00
Initial setting command transmission (4)
0xC0
0x05
0x00
Initial setting command transmission (5)
0xC0
0x03
0x00
Initial setting command transmission (6)
0xCE
0x01
0x00
Initial setting command transmission (7)
0xCE
0x00
0x00
Initial setting command transmission (8)
0x96
0xFF
0xFF
Initial setting command transmission (9)
0x98
0xFF
0xFF
Initial setting command transmission (10)
0x9A
0xFF
0xFF
Initial setting command transmission (11)
0x9C
0xFF
0xFF
Initial setting command transmission (12)
0x9E
0xFF
0xFF
Command transmission completion
confirmation (1)
0x01
(read)
0xC0 or 0x80
(read)
0x05
Command transmission completion
confirmation (2)
0x91
(read) 0x00
(read) 0x00
Common
setting
Segment value setting
0xC6
0x00-0x1F
(segment value)
0x00
Address value setting
0xC8
Lower 8 bits
Higher 8 bits
Busy signal confirmation
0xC5
0x1F (read)
0x01: BUSY
0x00: IDLE
Block
erase
Block erase command
0xC2
0x05
0x00
Chip
erase
Chip erase command
0xC2
0x06
0x00
For data
program
Code area programming data
(higher 2 bytes)
0xD2
Lower byte
Higher byte
Code area programming data
(lower 2 bytes)
0xCA
Lower byte
Higher byte
Data area programming data
0xCA
1-byte data
0xFF
Programming command
0xC2
0x04
0x00
For verify
Code area expected value data
(higher 2 bytes)
0xE4
Lower byte
Higher byte
Code area expected value data
(lower 2 bytes)
0xE2
Lower byte
Higher byte
Code area expected value data
0xE4
1-byte data
0x00
Verify command
0xC2
0x02
0x00
Confirm collation result of expected values
0xE7
(read)
0x01: OK
0x00: NG
(read)
0x00
[Note]
Ÿ
Programming the program area is performed in units of four bytes.
Set four byte boundaries (0H/4H/8H/CH) for lower four bits of the address.
Ÿ
Programming the data area is performed in units of one byte.
Содержание ML62Q1000 Series
Страница 17: ...Chapter 1 Overview...
Страница 112: ...Chapter 2 CPU and Memory Space...
Страница 154: ...Chapter 3 Reset Function...
Страница 166: ...Chapter 4 Power Management...
Страница 196: ...Chapter 5 Interrupts...
Страница 248: ...Chapter 6 Clock generation Circuit...
Страница 274: ...Chapter 7 Low Speed Time Base Counter...
Страница 291: ...Chapter 8 16 Bit Timer...
Страница 320: ...Chapter 9 Functional Timer FTM...
Страница 382: ...Chapter 10 Watchdog Timer...
Страница 402: ...Chapter 11 Serial Communication Unit...
Страница 456: ...Chapter 12 I2 C Bus Unit...
Страница 491: ...Chapter 13 I2 C Master...
Страница 512: ...Chapter 14 DMA Controller...
Страница 531: ...Chapter 15 Buzzer...
Страница 550: ...Chapter 16 Simplified RTC...
Страница 559: ...Chapter 17 GPIO...
Страница 594: ...Chapter 18 External Interrupt Function...
Страница 612: ...Chapter 19 CRC Generator...
Страница 632: ...Chapter 20 Analog Comparator...
Страница 644: ...Chapter 21 D A Converter...
Страница 655: ...Chapter 22 Voltage Level Supervisor...
Страница 676: ...Chapter 23 Successive Approximation Type A D Converter...
Страница 709: ...Chapter 24 Regulator...
Страница 714: ...Chapter 25 Flash Memory...
Страница 743: ...Chapter 26 Code Option...
Страница 750: ...Chapter 27 LCD Driver...
Страница 788: ...Chapter 28 On Chip Debug Function...
Страница 795: ...Chapter 29 Safety Function...
Страница 813: ...Appendix A...
Страница 881: ...Revision History...