![Krone Big Pack 1270 XC Скачать руководство пользователя страница 77](http://html1.mh-extra.com/html/krone/big-pack-1270-xc/big-pack-1270-xc_original-operating-instructions_2004793077.webp)
Initial operation
7
Adjusting universal shaft (for the version with “PreChop”)
7.5
BiG Pack 1270 XC
Original Operating Instructions 150000748_01_en
77
Drilling lubrication borehole into inner guard tube
Ø 25 mm
1
2
3
4
5
BP000-401
Place the inner guard tube (2) next to the outer section tube (4) so that the slide ring lock (5)
is in alignment with the opening (1).
Mark the position (3) of the grease nipples on the inner guard tube (2).
Drill a borehole Ø 25 mm in the inner guard tube (2) and deburr it.
Mounting outer guard tube
7
2
6
1
2
1
2
5
3
4
I
BP000-403
Push the outer guard tube (7) onto the inner section tube and align it so that the stop (6) of
the slide ring and the opening of the guard funnel (2) are in alignment.
Turn the collar (1) until you can feel a stop, refer to detail (I).
Mount the 3 screws (5).
Use a screwdriver (3) to pull the collar (1) over the locks (4) of the guard funnel (2)
Содержание Big Pack 1270 XC
Страница 29: ...Safety 2 Safety labels on the machine 2 5 BiG Pack 1270 XC Original Operating Instructions 150000748_01_en 29 ...
Страница 370: ...II T P LS I III IV T P S1 S2 M1 M2 V1 V2 P1 B1 A1 B2 B1 T1 T T4 P 180 bar B36 100 bar B11 B35 150101911_00 2 4 ...
Страница 372: ...B17 K9 K11 K12 B B1 A A1 1 2 3 K13 3 4 5 1 2 150101911_00 3 4 ...
Страница 374: ...B17 K11 1 2 150101911_00 4 4 ...
Страница 376: ... LUFXLW GLDJUDP GRFXPHQW QR YHUVLRQ ODUJH VTX XDUH EDOHU L 3 LJK 6SHHG XW 9DUL XW 3 3 1 0HGLXP RPIRUW IURP PDFKLQH QR ...