![Krone Big Pack 1270 XC Скачать руководство пользователя страница 252](http://html1.mh-extra.com/html/krone/big-pack-1270-xc/big-pack-1270-xc_original-operating-instructions_2004793252.webp)
16
Settings
16.24 Checking/setting Variable Filling System (VFS)
252
BiG Pack 1270 XC
Original Operating Instructions 150000748_01_en
For "MultiBale" version
NOTICE
Damage to the machine due to moving the sensing rake
In order to avoid damage to the machine, never modify the position of the sensing rake (11).
INFORMATION
Just move the sensing rake (11) if the triggering sensitivity cannot be set via spring,
.
BPG000-048
ü
The machine is shut down and safeguarded,
.
If the bale shape is still not satisfactory after the triggering sensitivity has been extended to the
maximum, install the sensing rake (11) in the next higher position.
If the overload protection still responds too frequently after the triggering sensitivity has been
reduced to the maximum, install the sensing rake (11) in the next lower position.
Moving the sensing rake
Loosen the hexagon head screw (17).
Move the sensing rake (11) into the desired position.
Tighten the hexagon head screw (17).
After moving the sensing rake, check or if necessary adjust the following settings:
Check zero position,
.
Check the triggering sensitivity and adjust it, if necessary,
.
Check the stop for the sensing rake and adjust it, if necessary,
Check the absorbing unit and adjust it, if necessary,
Содержание Big Pack 1270 XC
Страница 29: ...Safety 2 Safety labels on the machine 2 5 BiG Pack 1270 XC Original Operating Instructions 150000748_01_en 29 ...
Страница 370: ...II T P LS I III IV T P S1 S2 M1 M2 V1 V2 P1 B1 A1 B2 B1 T1 T T4 P 180 bar B36 100 bar B11 B35 150101911_00 2 4 ...
Страница 372: ...B17 K9 K11 K12 B B1 A A1 1 2 3 K13 3 4 5 1 2 150101911_00 3 4 ...
Страница 374: ...B17 K11 1 2 150101911_00 4 4 ...
Страница 376: ... LUFXLW GLDJUDP GRFXPHQW QR YHUVLRQ ODUJH VTX XDUH EDOHU L 3 LJK 6SHHG XW 9DUL XW 3 3 1 0HGLXP RPIRUW IURP PDFKLQH QR ...