slots 2 to 4 or 6 to 8, connecting to the 20-gigabit connector in slots 2 or 6,
respectively. [PR/444511]
■
On SRX5600 devices, during a Routing Engine reboot when processes are being
shut down, a rare race condition occurs that can lead to a Routing Engine kernel
crash. [PR/488484]
Infrastructure
■
On J Series devices, you cannot use a USB device that provides U3 features (such
as the U3 Titanium device from SanDisk Corporation) as the media device during
system boot. You must remove the U3 support before using the device as a boot
medium. For the U3 Titanium device, you can use the U3 Launchpad Removal
Tool on a Windows-based system to remove the U3 features. The tool is available
for download at
http://www.sandisk.com/Retail/Default.aspx?CatID=1415
. (To restore
the U3 features, use the U3 Launchpad Installer Tool accessible at
http://www.sandisk.com/Retail/Default.aspx?CatID=1411
). [PR/102645]
■
On J Series devices, if the device does not have an ARP entry for an IP address,
it drops the first packet from itself to that IP address. [PR/233867]
■
On J Series devices, when you press the F10 key to save and exit from BIOS
configuration mode, the operation might not work as expected. As a workaround,
use the
Save and Exit
option from the
Exit
menu. This issue can be seen on the
J4350 and J6350 routers with BIOS Version 080011 and on the J2320 and J2350
routers with BIOS Version 080012. [PR/237721]
■
On J Series devices, the
Clear NVRAM
option in the BIOS configuration mode
does not work as expected. This issue can be seen on the J4350 and J6350 routers
with BIOS Version 080011 and on the J2320 and J2350 routers with BIOS Version
080012. To help mitigate this issue, note any changes you make to the BIOS
configuration so that you can revert to the default BIOS configuration as needed.
[PR/237722]
■
On J Series devices, If you enable security trace options, the log file might not
be created in the default location at
/var/log/security-trace
. As a workaround,
manually set the log file to the directory
/var/log/security-trace
. [PR/254563]
■
On SRX3400, SRX3600, SRX5600, and SRX5800 devices, the SNMP set for the
MIB object
usmUserPrivKeyChange
does not work. [PR/482475]
Integrated Convergence Services
The following issues currently exist in SRX210 and SRX240 devices with Integrated
Convergence Services:
■
On SRX210 devices with Integrated Convergence Services, the call hold feature
does not work for Xlite softphones. [PR/432725]
■
At least one time slot must be configured for data for voice channels on T1 lines
to work. [PR/442932]
■
On SRX240 devices with Integrated Convergence Services, T1 configuration does
not support all the 24 time slots for voice calls. It is limited to 5 time slots or line
channels currently. [PR/442934]
■
The music-on-hold feature is not supported for SIP phones. [PR/443681]