If a firewall
show
command is followed by the
clear
command in a very quick
succession, there is a possibility that the
show
command will time out. If the
show
command is issued after a few seconds (5 seconds ideally), this issue will
not be seen. [PR/479497]
■
With JUNOS Releases 10.0 and 10.1, Trio DPCs do not support more than 31
remote PEs in a VPLS instance. Also, they do not support more than 31 AE
bridging logical interfaces in a bridge domain. [PR/488139]
■
When services PICs (SP) are bundled using Redundancy Services PIC (RSP)
interface hot-standby and if the RSP interface is configured to run on hot-standby
mode and if multiple graceful Routing Engine switchovers (GRES) are executed,
then the Routing Engine running as the backup might crash producing a core
file. [PR/492127]
■
When link trace entries are added in the path database, there is no check to
determine if the current number of entries have reached the path database size.
Because of this, the entries may grow to be greater than the path database size
(configured or default). [PR/494584]
■
Under certain circumstances a backup Routing Engine reboot followed by a
Routing Engine failover can cause the LACP to flap, which causes AE bundles to
flap. [PR/502937]
■
If a T640-FPC4-ES is installed in a T1600 router and an SIB statistics collection
is performed, the message log might report "JBUS: U32 read error, client .." only
if one of the SIBs is faulted or in the offline state. This system log message will
also appear if the T640-FPC4-ES FPC is removed from the chassis. There is no
operational impact. [PR/504363]
■
On MX Series routers with JUNOS Release 10.0R2 or higher, the backup Routing
Engine might report the following warning message upon commit once network
service is configured under the chassis stanza: "WARNING: network services flag
has been changed, please reboot system." [PR/505690]
■
When trigger hold timer UP/DOWN values for a defect condition is configured
or changed from the CLI, the up or down timer for the defect is started, based
on the current defect condition in the hardware. If the timer value is large enough
and the defect condition is changed in the hardware when the timer is still
running, a new defect will be reflected in the alarms only after the timer has
expired. [PR/509890]
■
When the 1x10GE XENPAK PIC is brought online, related error messages are
seen in the logs but without any functional impact. [PR/512094]
■
The output of the
show chassis hardware
command may not display the SIB
details when the SIB is inserted in the slot. [PR/515789]
■
On some XENPAK modules, the output of the
show chassis hardware
command
shows the message "NON-JNPR UNKNOWN" when the FPC is booted. There is
no impact on the traffic. To solve this issue, take the PIC offline and bring it back
online. [PR/516411]
■
On an M120, M7i or M10i router with Enhanced CFEB running JUNOS Release
10.0 and a VRF routing instance configured with vrf-table-label, the VPN traffic
might not flow when an ATM II IQ PIC is used for a core-facing link. [PR/516485]
■
On IQ2 and IQ2E 10GE PICs operating in WAN-PHY mode, the path trace
information does not get transmitted to the remote end. [PR/518331]
Issues in JUNOS Release 10.1 for M Series, MX Series, and T Series Routers
■