On EX2200 switches, the MIB OID
ipv6Forwarding
indicates that IPv6 is supported
even though IPv6 is not supported. The value of the
ipv6Forwarding.0
MIB object
is 1. [PR/473128]
■
If you attempt to set the time zone to
Europe/Berlin
on a switch with dual Routing
Engines, the
commit
command might fail. [PR/483273]
Interfaces
■
On EX8200 switches, aggregated Ethernet interfaces might go down and come
back up for a few minutes while the switch is updating many routes. [PR/416976]
J-Web Interface
■
In the J-Web interface, you cannot commit some configuration changes in the
Ports Configuration page and VLAN Configuration page because of the following
limitations for port mirroring ports and port mirroring VLANs:
■
A port configured as the output port for an analyzer cannot be a member of
any VLAN other than the default VLAN.
■
A VLAN configured to receive analyzer output can be associated with only
one port.
[PR/400814]
■
In the J-Web interface, uploading a software package to the switch might not
work properly if you are using Internet Explorer version 7. [PR/424859]
■
If an SRE module, RE module, SF module, line card, or Virtual Chassis member
is in offline mode, the J-Web interface might not update the dashboard image
accordingly. [PR/431441]
■
In the J-Web interface, in the Port Security Configuration page, you are required
to configure
action
when you configure
MAC limit
even though configuring an
action
value is not mandatory in the CLI. [PR/434836]
■
In the J-Web interface, in the OSPF Global Settings table in the OSPF Configuration
page, the Global Information table in the BGP Configuration page, or the Add
Interface window in the LACP Configuration page, if you try to change the position
of columns using the drag-and-drop method, only the column header moves to
the new position instead of the entire column. [PR/465030]
■
In the J-Web interface, in the OSPF Configuration page (
Configuration > Routing
> OSPF
), the Traceoptions tab in the Edit Global Settings window does not
display the available flags (tracing parameters). As a workaround, use the CLI to
view the available flags. [PR/475313]
■
When you have a large number of static routes configured and if you have
navigated to pages other than page 1 in the Route Information table in the J-Web
interface (
Monitor > Routing > Route Information
), changing the
Route Table
to query other routes refreshes the page but does not return to page 1. For
example, if you run the query from page 3 and the new query returns very few
results, the Results table continues to display page 3 and shows no results. To
view the results, navigate to page 1 manually. [PR/476338]
Outstanding Issues in JUNOS Release 10.1 for EX Series Switches
■
193