In some cases during the periodic error status monitoring, error messages such
as “Wi seg ucode discards in fabric stream” may be displayed on adjacent
streams. These messages are cosmetic and can be ignored. [PR/481344: This
issue has been resolved.]
■
When loopback is configured on t3 under ct3, t1 under ct1, or e1 under ce1, no
error syslog message is logged. Additionally, the
show interface extensive
command on the t3/t1/e1 displays "loopback" even though it is not actually
applied. [PR/486424: This issue has been resolved.]
■
The DPC remains in the ready state and the demux0 interface remains in a down
state after a chassisd restart without graceful Routing Engine switchover (GRES)
enabled. [PR/492961: This issue has been resolved.]
■
The AE logical interface flaps when the PIC that has the active link-protection
member link is taken offline. [PR/493492: This issue has been resolved.]
■
The No Redundant Config alarm that occurs in JUNOS Release 10.0 and above
after a PEM is shut down is invalid and is a non-impacting alarm message.
[PR/498089: This issue has been resolved.]
■
The one port OC12-3 PIC cannot support eight queues when the
no-concatenate
option is configured. [PR/499452: This issue has been resolved.]
■
On a 4–port ChOC3/STM1 and 12–port T1/E1 circuit emulation PICs, the ATM
logical interface packets counter does not increment if the PIC is configured in
the ATM IMA mode. [PR/500153: This issue has been resolved.]
■
When t1-options are configured at the
[edit interfaces ct1-x/y/z]
hierarchy level,
some ct1 interfaces of a 10xCHT1 IQ PIC might flap when the configuration
changes are committed. As a workaround, remove the t1-options. [PR/500820:
This issue has been resolved.]
■
Polling
ifInOctets
on Gigabit Ethernet IQ PIC VLANs might momentarily return a
higher value. [PR/500852: This issue has been resolved.]
■
On 40x1 Gigabit Ethernet PICs, very short fragments of fragmented TCP, UDP,
and ICMP packets may be incorrectly dropped with the diagnostic L4 length too
short. [501526: This issue has been resolved.]
■
The configured TTL set for GRE traffic is set properly for locally generated Routing
Engine packets, but is not set properly for transit packets. There is no
workaround. [PR/502087: This issue has been resolved.]
■
During a link UP/DOWN transition, jsscd may crash as a result of a NULL message
dereferencing by jsscd. [PR/502745: This issue has been resolved.]
■
In JUNOS Release 10.1, if the Neo MPCs power up while the A-DPCs are offline,
and if ISSU is performed, the MPCs will crash. [PR/502837: This issue has been
resolved.]
■
When an ATM AIS cell is received from the virtual channel under vlan-vci-ccc
encapsulation, the logical interface will be incorrectly marked down. There is no
workaround. [PR/503653: This issue has been resolved.]
■
When the
show lacp interface aex
command is used for a nonexistent AE interface,
no error is returned. [PR/503806: This issue has been resolved.]
Issues in JUNOS Release 10.1 for M Series, MX Series, and T Series Routers
■
67
Issues in JUNOS Release 10.1 for M Series, MX Series, and T Series Routers