WXC Integrated Services Module
■
When two J Series devices with WXC Integrated Services Modules (WXC ISM
200s) installed are configured as peers, traceroute fails if
redirect-wx
is configured
on both peers. [PR/227958]
■
On J6350 devices, JUNOS Software does not support policy-based VPN with WXC
Integrated Services Modules (WXC ISM 200s). [PR/281822]
Resolved Issues in JUNOS Release 10.1 for SRX Series Services Gateways
and J Series Services Routers
The following issues from JUNOS Release 10.0 R1 have been resolved with this
release. The identifier following the description is the tracking number in our bug
database.
Authentication
■
On SRX3400, SRX3600, SRX5600, and SRX5800 devices, when a firewall
authentication session was initiated, the authentication entry was created on all
the SPUs. However, in JUNOS Release 10.1 when multiple firewall authentication
sessions were initiated by the same user simultaneously, authentication entries
were not created in all the SPUs. As a result, some sessions timed out, and the
user had to reconnect or retry to reach the server. [PR/475706: This issue has
been resolved.]
Chassis Cluster
■
On SRX3400 and SRX3600 devices in a chassis cluster, ESP authentication errors
occurred while traffic was sent through 4000 site-to-site IPsec tunnels.
[PR/426073: This issue has been resolved.]
■
On SRX650 and J Series devices, doing a redundancy group 0 failover with 1000
logical interfaces on the
reth
interface caused replication errors. As a result, the
ksyncd
process generated a core file. [PR/428636: This issue has been resolved.]
■
On SRX5600 and SRX5800 devices in a chassis cluster, whenever the
reth
interface with static MAC address was configured, the ping operation failed from
the directly connected device to the chassis cluster. [PR/455051: This issue has
been resolved.]
■
On SRX3400, SRX3600, SRX5600, and SRX5800 devices, the track IP did not
display the correct status if the
ip-monitor
configuration was under RG0.
[PR/482556: This issue has been resolved.]
■
On SRX Series devices configured in a chassis cluster, the following informative
messages were erroneously displayed during failover, possibly creating the
incorrect impression that errors had occurred:
■
l2ha_set_rg_state: Setting rg state for 1 (MASTER)
■
l2ha_set_rg_state: Setting rg state for 1 (BACKUP)
[PR/498010: This issue has been resolved.]
158
■
Issues in JUNOS Release 10.1 for SRX Series Services Gateways and J Series Services Routers
JUNOS 10.1 Software Release Notes