Protocol (IPCP) sessions and renegotiate them if the remote side has changed
interface MTU settings prior to the switchover event. [PR/61121]
■
For Automatic Protection Switching (APS) on SONET/SDH interfaces, there are
no operational mode commands that display the presence of APS mode
mismatches. An APS mode mismatch occurs when one side is configured to use
bidirectional mode, and the other side is configured to use unidirectional mode.
[PR/65800]
■
The output of the
show interfaces diagnostics optics
command includes the "Laser
rx power low alarm" field even if the transceiver is a type (such as XENPAK) that
does not support this alarm. [PR/103444]
■
On the M120 router, hot swapping the fan tray might cause the
Check CB
alarm
to activate. [PR/268735]
■
On the JCS1200 platform, when you issue the
clear -config -T switch[1]
command
using the management module, the switch module returns to its factory default
setting instead of the Juniper Networks default setting. As a workaround, do not
issue the command. [PR/274399]
■
On the Juniper Control System (JCS) platform, the control and management
traffic for all Routing Engines shares the same physical link on the same switch
module. In rare cases, the physical link might become oversubscribed, causing
the management connection to Protected System Domains (PSDs) to be dropped.
[PR/293126]
■
On a Protected System Domain (PSD) configured with a large number of BGP
peers and routes (for example, 5000 peers and 1,000,000 routes), FPCs might
restart during a graceful Routing Engine switchover (GRES). [PR/295464]
■
When two routers are connected via SONET/SDH interfaces that are configured
as container interfaces and the Routing Engine on one router reboots, the
container interfaces on the other router might go down and come up again.
[PR/302757]
■
When forwarding-options is configured without route-accounting, commit goes
through with the message, "Could not retrieve the route-accounting." However,
no functionality is affected. [PR/312933]
■
While using an AE-20 on a TX matrix router, the AE link might not respond after
the chassis control is restarted. As a workaround, deactivate and activate the AE
interface. [PR/458926]
■
The bridge-domain MAC learn limit on the Packet Forwarding Engine can
sometimes become negative if the bridge domain is deleted and added
immediately as part of a configuration change. If that happens, the MAC learning
on that bridge domain can be affected. As a workaround, deactivate and activate
the bridge domain or VPLS routing instance configuration. [PR/467549]
■
Due to a larger number of components on the Neo board, it takes more time to
boot up than a comparable MX Series boards. [PR/468665]
■
When lockout is configured and the router is rebooted, the working router is
stuck in the wait-to-restore state while the protect router still shows channel state
working and no requests, but no longer shows the lockout flag. [PR/474482]
■
On restart with a large-scale configuration (16K IFLs per MPC), the
MPC-3D-16XGE-SFPP card may take up to 15 minutes to come up. [PR/478548]
56
■
Issues in JUNOS Release 10.1 for M Series, MX Series, and T Series Routers
JUNOS 10.1 Software Release Notes