JD780A Series Analyzers
Using Cable and Antenna Analyzer
511
NOTE
You can use the
LIMIT
hot key to analyze your measurements with the user-definable
limit and Pass/Fail indication. See
“Setting limit for cable and antenna analyzer” on page
516 for more information.
NOTE
You can go to
MEASURE SETUP
> Zone
to view your measurements in detail with the
user-definable zoom zones. See
“Setting zoom zones” on page 515 for more information.
Performing Smith chart measurements
The Smith Chart measurement is used to measure DUTs
’ impedance and phase to properly tune RF
devices. Smith chart also displays impedance-matching characteristics in cable and antenna systems
or filter and duplexer devices.
Making a measurement
Procedure
1.
Make a proper cable connection as described in “Connecting a cable for reflection, DTF, 1-port
phase, and Smith Chart measurements
2.
Press the
MEASURE SETUP
hot key.
3.
Press the
Data Points
soft key to change the resolution of your measurement, and then select
the data point option:
126
,
251
,
501
,
1001
, and
2001
. Changing the data point does not affect
current calibration.
NOTE
The larger number you choose, the higher resolution you get and the longer the
instrument takes to sweep and display results. Selecting the data point larger than what
you need for a measurement will result in unnecessarily long sweep time. It is
recommended that you select high resolution data points only for an instance of
measuring wide frequency bands or requiring precise measurement data.
4.
Optional
. To turn the bias tee on, complete the following steps:
a.
Toggle the
Bias Tee
soft key and select
On
.
b.
Enter a value between 12 and 32 with 0.1 V step.
c.
Enter the
V
soft key.
NOTE
The instrument’s built-in bias tee function (option 002) supplies 12-32 VDC bias to active
devices through the
RF In
port, eliminating the need of an external power supply.
NOTE
See
“Performing reflection measurements” on page 502 for more information on how to
set other measurement setup parameters for the Smith Chart measurement.
Содержание CellAdvisor JD780A Series
Страница 52: ...JD780A Series Analyzers 52 Getting Started Figure 6 Example of Web remote on Chrome...
Страница 91: ...JD780A Series Analyzers Using Spectrum Analyzer 91 Figure 23 PIM detection for multiple carriers...
Страница 254: ...JD780A Series Analyzers 254 Using LTE FDD Signal Analyzer 3 RS SINR 4 S SS RSSI 5 P SS Power...
Страница 323: ...JD780A Series Analyzers Using LTE TDD Signal Analyzer 323 3 RS SINR 4 S SS RSSI 5 P SS Power...
Страница 390: ...JD780A Series Analyzers 390 Using EV DO Signal Analyzer 3 Pilot 4 MAC 64 5 MAC 128...
Страница 525: ......
Страница 590: ...JD780A Series Analyzers 590 Appendix Figure 306 Append keywords window...