JD780A Series Analyzers
556
Using Power Meter
Procedure
1.
Press the
FREQ/DIST
hard key.
2.
Press the
Frequency
soft key.
3.
Enter a value by using the numeric keys. You can also use the rotary knob.
4.
Select the unit:
GHz
,
MHz
,
kHz
, or
Hz
.
Setting amplitude
Procedure
1.
Press the
AMP/SCALE
hard key.
2.
Toggle the
Display
soft key and select the display method:
Relative
or
Absolute
.
3.
If the
Relative
is selected, press the Set Reference soft key to set the current value as the
reference.
4.
To specify the display range, complete the following steps:
a.
Press the
Display Maximum
soft key to set the maximum value for the power meter.
b.
Enter a value by using the numeric keys. You can also use the rotary knob.
c.
Press the
dBm
soft key.
d.
Press the
Display Minimum
soft key to set the minimum value for the power meter.
e.
Enter a value by using the numeric keys. You can also use the rotary knob.
f.
Press the
dBm
soft key.
5.
Optional
. To enable the external offset, complete the following steps:
a.
Toggle the
External Offset
soft key and select
On
.
b.
Enter a value between 0 and 60 by using the numeric keys.
c.
Press the
dB
soft key.
Making a measurement
Procedure
1.
Press the
MEASURE
hot key.
2.
Depending your connected power sensor, do one of the following:
–
For JD736B, select the power range option:
Average Power
,
Peak Power
, or
Pulse Power
.
–
For JD734B, select
Peak Power
.
–
For JD732B, select
Average Power
.
–
For JD731B, select the power range option:
Forward Avg Power
,
Reverse Avg Power
,
Forward Peak Power
,
Pulse Power
, or
VSWR
.
–
For JD733A, select the power range option:
Forward Avg Power
,
Reverse Avg Power
,
Forward Peak Power
, or
VSWR
.
3.
Press the
MEASURE SETUP
hot key.
4.
Press the
Resolution
soft key, and then select the resolution option from the following choices:
–
0
to display the reading with no zero decimal place
–
1
to display the reading with one decimal place
Содержание CellAdvisor JD780A Series
Страница 52: ...JD780A Series Analyzers 52 Getting Started Figure 6 Example of Web remote on Chrome...
Страница 91: ...JD780A Series Analyzers Using Spectrum Analyzer 91 Figure 23 PIM detection for multiple carriers...
Страница 254: ...JD780A Series Analyzers 254 Using LTE FDD Signal Analyzer 3 RS SINR 4 S SS RSSI 5 P SS Power...
Страница 323: ...JD780A Series Analyzers Using LTE TDD Signal Analyzer 323 3 RS SINR 4 S SS RSSI 5 P SS Power...
Страница 390: ...JD780A Series Analyzers 390 Using EV DO Signal Analyzer 3 Pilot 4 MAC 64 5 MAC 128...
Страница 525: ......
Страница 590: ...JD780A Series Analyzers 590 Appendix Figure 306 Append keywords window...