![JDS Uniphase CellAdvisor JD780A Series Скачать руководство пользователя страница 184](http://html1.mh-extra.com/html/jds-uniphase/celladvisor-jd780a-series/celladvisor-jd780a-series_user-manual_3602616184.webp)
JD780A Series Analyzers
184
Using WCDMA/HSPA+ Signal Analyzer
4.
To select the standard channel, complete the following steps:
a.
Press the
Channel Std
soft key. The standard channel window appears.
See
“Appendix C – Band, frequency & channel standard” on page 571 for more information.
b.
Select the band to be measured by using the rotary knob, the arrow keys, or the
Page
Up/Page Down
soft keys.
c.
Press the
Select
soft key or the rotary knob to confirm the selection.
5.
To set the channel number for the selected index, complete the following steps:
a.
Press the
Channel Number
soft key.
b.
Enter a value by using the numeric keys. You can also use the rotary knob.
c.
Press the
Enter
soft key.
The instrument displays a corresponding center frequency for the channel number.
6.
To set the integration bandwidth for the selected index, complete the following steps:
a.
Press the
Integration Bandwidth
soft key.
b.
Enter a value by using the numeric keys. You can also use the rotary knob.
c.
Select the unit:
GHz
,
MHz
,
kHz
, or
Hz
.
7.
To add more channels to be scanned, repeat steps
3-6
.
8.
Press the
ESC
hard key to dismiss the channel list window and view the scanning result.
To set the frequencies to be scanned:
1.
Press the
FREQ/DIST
hard key.
2.
Toggle the
Unit
soft key and select
Freq
.
3.
Press the
Index
soft key, and then enter an index number by turning the rotary knob or using the
numeric keys.
4.
To set the center frequency for the selected index, complete the following steps:
a.
Press the
Center Frequency
soft key.
b.
Enter a value by using the numeric keys. You can also use the rotary knob.
c.
Select the unit:
GHz
,
MHz
,
kHz
, or
Hz
.
5.
To set the integration bandwidth for the selected index, complete the following steps:
a.
Press the
Integration Bandwidth
soft key.
b.
Enter a value by using the numeric keys. You can also use the rotary knob.
c.
Select the unit:
GHz
,
MHz
,
kHz
, or
Hz
.
6.
To add more channels to be scanned, repeat steps
3-5
.
7.
Press the
ESC
hard key to dismiss the channel list window and view the scanning result.
Setting limit for OTA channel scanner
Procedure
1.
Press the
LIMIT
hot key.
2.
Press the
Limit Line
soft key to set a threshold for the limit line and Pass/Fail indication.
3.
Enter a value, and then press the
dBm
unit soft key.
4.
Toggle the
Limit Line
soft key between
On
and
Off
to display or dismiss the limit line.
5.
Optional
. You can enable alarm sound that goes off if the measurement falls outside of the limit.
Toggle the
Beep
soft key between
On
and
Off
to enable or disable the beep sound.
Содержание CellAdvisor JD780A Series
Страница 52: ...JD780A Series Analyzers 52 Getting Started Figure 6 Example of Web remote on Chrome...
Страница 91: ...JD780A Series Analyzers Using Spectrum Analyzer 91 Figure 23 PIM detection for multiple carriers...
Страница 254: ...JD780A Series Analyzers 254 Using LTE FDD Signal Analyzer 3 RS SINR 4 S SS RSSI 5 P SS Power...
Страница 323: ...JD780A Series Analyzers Using LTE TDD Signal Analyzer 323 3 RS SINR 4 S SS RSSI 5 P SS Power...
Страница 390: ...JD780A Series Analyzers 390 Using EV DO Signal Analyzer 3 Pilot 4 MAC 64 5 MAC 128...
Страница 525: ......
Страница 590: ...JD780A Series Analyzers 590 Appendix Figure 306 Append keywords window...