![JDS Uniphase CellAdvisor JD780A Series Скачать руководство пользователя страница 471](http://html1.mh-extra.com/html/jds-uniphase/celladvisor-jd780a-series/celladvisor-jd780a-series_user-manual_3602616471.webp)
JD780A Series Analyzers
Using Mobile WiMAX Signal Analyzer
471
–
To select the detect mode, press the
Detect Mode
soft key and then select the option:
Auto
,
QPSK
,
16 QAM
, or
64 QAM
.
Setting limit for power vs. time tests
Procedure
1.
Press the
LIMIT
hot key.
2.
Press the
PvsT Test Limits
soft key.
3.
Select the test item(s) and set the limit(s):
To set the limit for
Select
Set
Preamble power
Preamble Power
High Limit, Low Limit
Downlink burst power
DL Burst Power
High Limit, Low Limit
Uplink burst power
UL Burst Power
High Limit, Low Limit
Frame average power
Frame Average Power
High Limit, Low Limit
Time offset
Time Offset
High Limit, Low Limit
I/Q origin offset
IQ Origin Offset
High Limit
4.
Optional
. You can enable alarm sound that goes off if the measurement falls outside of the limit.
Toggle the
Beep
soft key between
On
and
Off
to enable or disable the beep sound.
5.
Optional
. Go to
SAVE/LOAD
> Save
, and then select
Limit
to save the limit settings.
See
“Using save” on page 31 for more information.
Measurement example
Figure 235
Power vs. time (frame) measurement with Mobile WiMAX signal analyzer
Содержание CellAdvisor JD780A Series
Страница 52: ...JD780A Series Analyzers 52 Getting Started Figure 6 Example of Web remote on Chrome...
Страница 91: ...JD780A Series Analyzers Using Spectrum Analyzer 91 Figure 23 PIM detection for multiple carriers...
Страница 254: ...JD780A Series Analyzers 254 Using LTE FDD Signal Analyzer 3 RS SINR 4 S SS RSSI 5 P SS Power...
Страница 323: ...JD780A Series Analyzers Using LTE TDD Signal Analyzer 323 3 RS SINR 4 S SS RSSI 5 P SS Power...
Страница 390: ...JD780A Series Analyzers 390 Using EV DO Signal Analyzer 3 Pilot 4 MAC 64 5 MAC 128...
Страница 525: ......
Страница 590: ...JD780A Series Analyzers 590 Appendix Figure 306 Append keywords window...