3.
Toggle the
Interference ID
soft key between
On
and
Off
to turn the Interference ID on and off.
4.
To set the threshold level manually, complete the following steps:
a.
Press the
Threshold
soft key.
b.
Enter a value by using the numeric keys.
c.
Press the
dBm
soft key.
5.
Optional
. Go to
SAVE/LOAD
> Save
, and then select the save option from the choices available
for your measurement mode. See
“Using save” on page 31 for more information.
NOTE
You can use the
LIMIT
hot key to analyze your measurements with the display line, multi-
segment line, and channel limit. See
“Setting limit for interference analyzer” on page 119
for more information.
Conducting interference measurements
Spectrogram
The Spectrogram is particularly useful when attempting to identify periodic or intermittent signals as it
captures spectrum activity over time and uses various colors to differentiate spectrum power levels.
When the directional antenna is used to receive the signal, you will see a change in the amplitude of
the tracked signal as you change the direction of the antenna and see a change in the Spectrogram
colors. The source of the signal is located in the direction that results in the highest signal strength.
Setting measure setup
Procedure
1.
Configure test parameters as described in the
“Configuring test parameters” on page 95.
2.
Press the
MEASURE SETUP
hot key.
3.
To set the amount of time between each trace measurement:
a.
Press the
Time Interval
soft key.
b.
Enter a value by using the numeric keys. You can also use the rotary knob.
c.
Press the
Sec
soft key.
4.
To set the time cursor on a specific trace position, complete the following steps:
a.
Toggle the
Time Cursor
soft key and select
On
.
b.
Turn the rotary knob to move the time cursor. You can also enter a value and then press the
Enter
soft key.
NOTE
Enabling the time cursor puts the measurement on hold and you can make post-
processing analysis for each measurement over time using the time cursor.
5.
To start a new measurement, press the
Reset/Restart
soft key.
6.
Optional
. Go to
SAVE/LOAD
> Save
, and then select the save option from the choices available
for your measurement mode. See
“Using save” on page 31 for more information.
Measurement example
The spectrogram shows a vertical line on the chart when the marker is enabled on the screen.
Содержание CellAdvisor JD780A Series
Страница 52: ...JD780A Series Analyzers 52 Getting Started Figure 6 Example of Web remote on Chrome...
Страница 91: ...JD780A Series Analyzers Using Spectrum Analyzer 91 Figure 23 PIM detection for multiple carriers...
Страница 254: ...JD780A Series Analyzers 254 Using LTE FDD Signal Analyzer 3 RS SINR 4 S SS RSSI 5 P SS Power...
Страница 323: ...JD780A Series Analyzers Using LTE TDD Signal Analyzer 323 3 RS SINR 4 S SS RSSI 5 P SS Power...
Страница 390: ...JD780A Series Analyzers 390 Using EV DO Signal Analyzer 3 Pilot 4 MAC 64 5 MAC 128...
Страница 525: ......
Страница 590: ...JD780A Series Analyzers 590 Appendix Figure 306 Append keywords window...