![JDS Uniphase CellAdvisor JD780A Series Скачать руководство пользователя страница 388](http://html1.mh-extra.com/html/jds-uniphase/celladvisor-jd780a-series/celladvisor-jd780a-series_user-manual_3602616388.webp)
JD780A Series Analyzers
388
Using EV-DO Signal Analyzer
Conducting modulation measurements
In order to make accurate measurements of time offset and PN, you must connect an external trigger
before making a modulation measurement.
Constellation
The Constellation is used to observe some aspects of modulation accuracy and can reveal certain
fault mechanisms such as I/Q amplitude imbalance or quadrature imbalance. It displays constellation
diagram by modulation types.
Setting measure setup
After configuring test parameters as described in the
“Configuring test parameters” on page 373, you
can continue your measurement. The measurement settings can be saved and recalled as a file. You
can also use JDViewer, PC application software to configure a measure setup, save as a file, and load
the file on to the instrument.
Procedure
1.
Press the
MEASURE SETUP
hot key.
2.
To set the Pseudo-Noise (PN) offset, complete the following steps:
a.
Toggle the
PN Offset
soft key between
Auto
and
Manual
.
b.
Enter a value by using the numeric keys to set manually.
c.
Press the
Enter
soft key.
3.
To set the incremental step for the PN offset, complete the following steps:
a.
Press the
PN Increment
soft key.
b.
Enter a value by using the numeric keys.
c.
Press the
Enter
soft key.
4.
Press the
Detect Mode
soft key, and then select the detection mode option:
Auto
,
QPSK
,
8PSK
,
16 QAM
, or
64 QAM
.
5.
Optional
. Go to
SAVE/LOAD
> Save
, and then select the save option from the choices available
for your measurement mode. See
“Using save” on page 31 for more information.
NOTE
You can use the
LIMIT
hot key to analyze your measurements with the user-definable
limit and Pass/Fail indication. See
“Setting limit for modulation tests” on page 397 for
more information.
The Max Inactive is not used in the Constellation mode.
Содержание CellAdvisor JD780A Series
Страница 52: ...JD780A Series Analyzers 52 Getting Started Figure 6 Example of Web remote on Chrome...
Страница 91: ...JD780A Series Analyzers Using Spectrum Analyzer 91 Figure 23 PIM detection for multiple carriers...
Страница 254: ...JD780A Series Analyzers 254 Using LTE FDD Signal Analyzer 3 RS SINR 4 S SS RSSI 5 P SS Power...
Страница 323: ...JD780A Series Analyzers Using LTE TDD Signal Analyzer 323 3 RS SINR 4 S SS RSSI 5 P SS Power...
Страница 390: ...JD780A Series Analyzers 390 Using EV DO Signal Analyzer 3 Pilot 4 MAC 64 5 MAC 128...
Страница 525: ......
Страница 590: ...JD780A Series Analyzers 590 Appendix Figure 306 Append keywords window...