JD780A Series Analyzers
Using T1 Analyzer
535
–
2e23:
A pseudorandom pattern based on a 23 bit shift register.
–
2e15:
A pseudorandom pattern based on a 15 bit shift register.
–
2e23 INV:
Bit inversed pseudorandom pattern based on a 23 bit shift register.
–
2e15 INV:
Bit inversed pseudorandom pattern based on a 15 bit shift register.
6.
Toggle the
TX Clock
soft key between
Internal
and
RX
and select the timing source option to
measure frequency and timing:
–
Internal:
Internal clock uses an internal oscillator in case of external reference is not
available and the instrument does not transmit signal to synchronized equipment. The
instrument provides the clock to the unit under test and most cases in Loopback test mode.
–
RX:
Transmit clock uses the frequency recovered from the received signal (Network Loop),
if accurate frequency measurement is required.
7.
Press the
TX LBO
soft key, and then select the level for TX Line Build Out option from the
following choices:
–
0 dB:
Is used in most cases including that the test set is connected to the DSX front panel,
to CSU, to NIU or Channel Bank or that the cabling is less than about 130 feet in-between
test set and DSX.
–
-7.5 dB:
Is used in cases that attenuation is needed where the T1 line is series connected
to 7.5 dB attenuator.
–
-15 dB:
Is used in cases that attenuation is needed where the T1 line is series connected to
15 dB attenuator.
8.
Press the
Loop Codes
soft key, and then do one of the following option:
–
To select the link option, toggle press the
Link
soft key between
Inband
and
Datalink
.
Datalink is used when the framing is set to ESF.
–
To select the Channel Service Unit, press the
CSU
soft key.
–
To select the Network Interface Unit, press the
NIU
soft key.
To start or stop testing:
1.
Press the
MEASURE
hot key.
2.
Press the
Loop Test
soft key, and then select the testing option as needed:
Start
,
Stop
, or
Clear
.
To activate or deactiave the external loop back:
1.
Press the
Remote Loop Up
to activate the external loop back so that the instrument sends the
system a request of the loop back mode.
2.
Press the
Remote Loop Dn
to deactivate the external loop back so that the instrument sends
the system a request to clean the loop back mode.
To activate or deactiave the internal loop back:
1.
Press the
Self Loop Up
to activate the internal loop back.
2.
Press the
Self Loop Dn
to deactivate the internal loop back, reverting the instrument to a
through mode.
To select the error injection type:
1.
Press the
Error Injection
soft key, and then select the error injection type:
None
,
1E-3
,
1E-4
,
1E-5
, or
Single
.
To set the error injection optios:
1.
Press the
Alarm Injection
soft key.
2.
Toggle the
AIS Alarm
soft key between
On
and
Off
to enable or disable the Alarm Indication
Signal.
Содержание CellAdvisor JD780A Series
Страница 52: ...JD780A Series Analyzers 52 Getting Started Figure 6 Example of Web remote on Chrome...
Страница 91: ...JD780A Series Analyzers Using Spectrum Analyzer 91 Figure 23 PIM detection for multiple carriers...
Страница 254: ...JD780A Series Analyzers 254 Using LTE FDD Signal Analyzer 3 RS SINR 4 S SS RSSI 5 P SS Power...
Страница 323: ...JD780A Series Analyzers Using LTE TDD Signal Analyzer 323 3 RS SINR 4 S SS RSSI 5 P SS Power...
Страница 390: ...JD780A Series Analyzers 390 Using EV DO Signal Analyzer 3 Pilot 4 MAC 64 5 MAC 128...
Страница 525: ......
Страница 590: ...JD780A Series Analyzers 590 Appendix Figure 306 Append keywords window...