![JDS Uniphase CellAdvisor JD780A Series Скачать руководство пользователя страница 516](http://html1.mh-extra.com/html/jds-uniphase/celladvisor-jd780a-series/celladvisor-jd780a-series_user-manual_3602616516.webp)
JD780A Series Analyzers
516
Using Cable and Antenna Analyzer
need of an additional calibration.
Procedure
1.
Press the
MEASURE SETUP
hot key.
2.
Press the
Alt DTF Band Settings
soft key.
3.
Toggle the
Alt DTF Band
soft key and select
On
or
Off
to enable or disable the alternate band
feature.
4.
To set the start and stop distances for the alternate band, complete the following steps:
a.
Press the
Start Distance
soft key.
b.
Enter a value by using the numeric keys. You can also use the rotary knob or the arrow
keys.
c.
Select the
Enter
soft key.
d.
Press the
Stop Frequency
soft key.
e.
Enter a value by using the numeric keys. You can also use the rotary knob or the arrow
keys.
f.
Select the
Enter
soft key.
5.
To set the start and stop frequencies for the alternate band, complete the following steps:
a.
Press the
Alternate Start Frequency
soft key.
b.
Enter a value by using the numeric keys. You can also use the rotary knob or the arrow
keys.
c.
Select the unit:
GHz
,
MHz
,
kHz
, or
Hz
.
d.
Press the
Alternate Stop Frequency
soft key.
e.
Enter a value by using the numeric keys. You can also use the rotary knob or the arrow
keys.
f.
Select the unit:
GHz
,
MHz
,
kHz
, or
Hz
.
6.
To set the center and span frequencies for the alternate band, complete the following steps:
a.
Press the
Alternate Center Frequency
soft key.
b.
Enter a value by using the numeric keys. You can also use the rotary knob or the arrow
keys.
c.
Select the unit:
GHz
,
MHz
,
kHz
, or
Hz
.
d.
Press the
Alternate Span Frequency
soft key.
e.
Enter a value by using the numeric keys. You can also use the rotary knob or the arrow
keys.
f.
Select the unit:
GHz
,
MHz
,
kHz
, or
Hz
.
Setting limit for cable and antenna analyzer
Procedure
1.
Press the
LIMIT
hot key.
2.
Press the
Multi Segment Line
soft key for Pass/Fail indication.
3.
Toggle the
Limit
soft key between
Upper
and
Lower
to select the one to be displayed.
4.
Set the number of segments for the selected upper or lower limit line. You can set up to 50
segments.
a.
Press the
# of Line
soft key.
b.
Enter a value between 1 and 50 by using the numeric keys.
Содержание CellAdvisor JD780A Series
Страница 52: ...JD780A Series Analyzers 52 Getting Started Figure 6 Example of Web remote on Chrome...
Страница 91: ...JD780A Series Analyzers Using Spectrum Analyzer 91 Figure 23 PIM detection for multiple carriers...
Страница 254: ...JD780A Series Analyzers 254 Using LTE FDD Signal Analyzer 3 RS SINR 4 S SS RSSI 5 P SS Power...
Страница 323: ...JD780A Series Analyzers Using LTE TDD Signal Analyzer 323 3 RS SINR 4 S SS RSSI 5 P SS Power...
Страница 390: ...JD780A Series Analyzers 390 Using EV DO Signal Analyzer 3 Pilot 4 MAC 64 5 MAC 128...
Страница 525: ......
Страница 590: ...JD780A Series Analyzers 590 Appendix Figure 306 Append keywords window...