Appendix A Parameter Table
- 126 -
Para.
No.
Para. Name
Setting Range
Default
Property
FC-43
Acceleration/
deceleration time of
simple PLC reference
12
0 to 3
0
☆
FC-44 Running time of simple
PLC reference 13
0.0s(h) to 6553.5s(h)
0.0s(h)
☆
FC-45
Acceleration/
deceleration time of
simple PLC reference
13
0 to 3
0
☆
FC-46 Running time of simple
PLC reference 14
0.0s(h) to 6553.5s(h)
0.0s(h)
☆
FC-47
Acceleration/
deceleration time of
simple PLC reference
14
0 to 3
0
☆
FC-48 Running time of simple
PLC reference 15
0.0s(h) to 6553.5s(h)
0.0s(h)
☆
FC-49
Acceleration/
deceleration time of
simple PLC reference
15
0 to 3
0
☆
FC-50 Time unit of simple PLC
running
0: s (second)
1: h (hour)
0
☆
FC-51 Reference 0 source
0: FC-00 (Reference 0)
1: AI1
2: AI2
4: Pulse reference (DIO1)
5: PID
6: Set by preset frequency (F0-08),
modified via terminal UP/DOWN
0
☆
Group Fd: Communication Parameters
Fd-00 Modbus baud rate
0: 300 bps
1: 600 bps
2: 1,200 bps
3: 2,400 bps
4: 4,800 bps
5: 9,600 bps
6: 19,200 bps
7: 38,400 bps
8: 57,600 bps
9: 11,5200 bps
5
☆
Содержание MD810 Series
Страница 1: ...User Guide MD810 Series Standard Drive Multidrive System A04 Data code 19010518 User Guide...
Страница 37: ...2 Installation 36 External 24 V power supply Connect with the drive unit terminal Figure e Figure f Figure g...
Страница 38: ...2 Installation 37 Figure h Figure i Figure 2 7 HST 6004 HST 7004 DC soft charge unit installation...