2 Installation
- 24 -
2) Dual rack installation
Booksize Unit
Vertical Tower Unit
Air guide plate
Air guide plate
Air guide plate
Air guide plate
NOTE
◆
An insulation deflector may be selectively installed in the upper rack of
units during dual rack installation.
◆
Do not separately install two or fewer drive units.
◆
The through-hole mounting method supports only single rack installation.
2.2.2 Installation of the Drive Unit
1
Removal and Refitting of Covers
Remove and refit the covers according to the following procedure.
Removal
1) Turn upwards the translucent
upper cover of the operating
panel cover, and loosen the
screw for fastening the cover.
2) Remove the upper cover.
3)
Pull out the entire operating
panel box.