Appendix A Parameter Table
- 96 -
Para.
No.
Para. Name
Setting Range
Default
Property
F1-06
Asynchronous/
Synchronous motor
stator resistance
0.001 to 65.535 Ω (drive unit power
≤ 55 kW)
0.0001 to 6.5535Ω (drive unit power
> 55 kW)
Auto-tuned
★
F1-07
Asynchronous motor
rotor resistance
0.001 to 65.535 Ω (drive unit power
≤ 55 kW)
0.0001Ω to 6.5535Ω (drive unit
power > 55 kW)
Auto-tuned
★
F1-08
Asynchronous motor
leakage inductive
reactance
0.01 to 655.35 mH (drive unit power
≤ 55 kW)
0.001 to 65.535 mH (drive unit power
> 55 kW)
Auto-tuned
★
F1-09
Asynchronous motor
mutual inductive
reactance
0.1 to 6553.5mH (drive unit power ≤
55 kW)
0.01 to 655.35 mH (drive unit power
> 55 kW)
Auto-tuned
★
F1-10 Asynchronous motor
no-load current
0.01 A to F1-03 (drive unit power ≤
55 kW)
0.1 A to F1-03 (drive unit power > 55
kW)
Auto-tuned
★
F1-11
Asynchronous motor
iron-core saturation
coefficient 1
50.0% to 100.0%
86.0%
☆
F1-12
Asynchronous motor
iron-core saturation
coefficient 2
100.0% to 150.0%
130.0%
☆
F1-13
Asynchronous motor
iron-core saturation
coefficient 3
100.0% to 170.0%
140.0%
☆
F1-14
Asynchronous motor
iron-core saturation
coefficient 4
100.0% to 180.0%
150.0%
☆
F1-17
Synchronous motor
axis D inductance
0.01 to 655.35 mH (drive unit power
≤ 55 kW)
0.001 to 65.535 mH (drive unit power
> 55 kW)
Auto-tuned
★
F1-18 Synchronous motor
axis Q inductance
0.01 to 655.35 mH (drive unit power
≤ 55 kW)
0.001 to 65.535 mH (drive unit power
> 55 kW)
Auto-tuned
★
F1-19 Synchronous motor
back EMF
0.1 to 6553.5 V
Auto-tuned
★
F1-23
Friction torque
(percentage)
0.00% to 100.00%
0.00%
★