Appendix A Parameter Table
- 112 -
Para.
No.
Para. Name
Setting Range
Default
Property
Group F7: Operating panel and Display
F7-03 LED display running
parameter 1
0000 to FFFF
Bit00: Running frequency (Hz)
Bit01: Frequency reference (Hz)
Bit02: Bus voltage (V)
Bit03: Output voltage (V)
Bit04: Output Current (A)
Bit05: Output power (kW)
Bit06: Output torque (%)
Bit07: DI input status
Bit08: DO status
Bit09: AI1 voltage (V)
Bit10: AI2 voltage (V)
Bit11: Reserved
Bit12: Count value
Bit13: Length value
Bit14: Load speed display
Bit15: PID reference
1F
☆
F7-04 LED display running
parameters 2
0000 to FFFF
Bit00: PID feedback
Bit01: PLC stage
Bit02: Pulse reference frequency
(kHz)
Bit03: Running frequency (Hz)
Bit04: Remaining running time
Bit05: AI1 voltage before correction (V)
Bit06: AI2 voltage before correction (V)
Bit07: Reserved
Bit08: Linear speed
Bit09: Current power-on time (hour)
Bit10: Current running time (min)
Bit11: Pulse reference frequency (Hz)
Bit12: Communication setting value
Bit13: Encoder feedback speed (Hz)
Bit14: Main frequency display (Hz)
Bit15: Auxiliary frequency display
(Hz)