Technical Reference Manual
002-29852 Rev. *B
Bits Name
SW
HW
Default or
Enum
Description
6
DAR
RW
R
0
Disable Automatic Retransmission
0= Automatic retransmission of messages not
transmitted successfully enabled
1= Automatic retransmission disabled
7
TEST
RW
R
0
Test Mode Enable
0= Normal operation, register TEST holds reset values
1= Test Mode, write access to register TEST enabled
8
FDOE
RW
R
0
FD Operation Enable
0= FD operation disabled
1= FD operation enabled
9
BRSE
RW
R
0
Bit Rate Switch Enable
0= Bit rate switching for transmissions disabled
1= Bit rate switching for transmissions enabled
12
PXHD
RW
R
0
Protocol Exception Handling Disable
0= Protocol exception handling enabled
1= Protocol exception handling disabled
13
EFBI
RW
R
0
Edge Filtering during Bus Integration
0= Edge filtering disabled
1= Two consecutive dominant tq required to detect an
edge for hard synchronization
14
TXP
RW
R
0
Transmit Pause
If this bit is set, the M_TTCAN pauses for two CAN bit
times before starting the next transmission
after itself has successfully transmitted a frame (see
Section 3.5).
0= Transmit pause disabled
1= Transmit pause enabled
15
NISO
RW
R
0
Non ISO Operation
If this bit is set, the M_TTCAN uses the CAN FD frame
format as specified by the Bosch CAN FD
Specification V1.0.
0= CAN FD frame format according to ISO 11898-
1:2015
1= CAN FD frame format according to Bosch CAN FD
Specification V1.0 addressing the non-ISO CAN FD
55
2022-04-18
TRAVEO™ T2G Automotive MCU: TVII-B-E-4M body controller entry registers