28.4.1.1.18 TCPWM_GRP_CNT_TR_OUT_SEL
Description:
Counter output trigger selection register
Address:
0x40380054
Offset:
0x54
Retention:
Retained
IsDeepSleep:
No
Comment:
Used to select internal events for output trigger generation.
Default:
0x32
Bit-field Table
Bits
7
6
5
4
3
2
1
0
Name
None [7:7]
OUT1 [6:4]
None [3:3]
OUT0 [2:0]
Bits
15
14
13
12
11
10
9
8
Name
None [15:8]
Bits
23
22
21
20
19
18
17
16
Name
None [23:16]
Bits
31
30
29
28
27
26
25
24
Name
None [31:24]
Bit-fields
Bits Name
SW
HW
Default or
Enum
Description
0:2
OUT0
RW
R
2
Selects one of the internal events to generate the
output trigger 0. Default setting selects the terminal
count event.
OVERFLOW
0
Overflow event
UNDERFLOW
1
Underflow event
TC
2
Terminal count event (default selection)
CC0_MATCH
3
Compare match 0 event
CC1_MATCH
4
Compare match 1 event
LINE_OUT
5
PWM output signal 'line_out'
Reserved6
6
N/A
Disabled
7
Output trigger disabled.
4:6
OUT1
RW
R
3
Selects one of the internal events to generate the
output trigger 1. Default setting selects the compare
match 0 event.
OVERFLOW
0
Overflow event
UNDERFLOW
1
Underflow event
TC
2
Terminal count event
CC0_MATCH
3
Compare match 0 event (default selection)
CC1_MATCH
4
Compare match 1 event
LINE_OUT
5
PWM output signal 'line_out'
Reserved6
6
N/A
Disabled
7
Output trigger disabled.