Technical Reference Manual
002-29852 Rev. *B
26.8.16 PWR_SSV_STATUS
Description:
Supply Supervision Status Register
Address:
0x4026101C
Offset:
0x101C
Retention:
Retained
IsDeepSleep:
Yes
Comment:
Status for brownout and over-voltage detectors.
Default:
0x30505
Bit-field Table
Bits
7
6
5
4
3
2
1
0
Name
None [7:3]
BODVCCD
_OK [2:2]
BODVDDA
_OK [1:1]
BODVDDD
_OK [0:0]
Bits
15
14
13
12
11
10
9
8
Name
None [15:11]
OVDVCCD
_OK [10:10]
OVDVDDA
_OK [9:9]
OVDVDDD
_OK [8:8]
Bits
23
22
21
20
19
18
17
16
Name
None [23:18]
OCD
_DPSLP
_REG_OK
[17:17]
OCD_ACT
_LINREG
_OK [16:16]
Bits
31
30
29
28
27
26
25
24
Name
None [31:24]
Bit-fields
Bits Name
SW
HW
Default or
Enum
Description
0
BODVDDD_OK
R
RW
1
BOD indicates vddd is ok. This will always read 1,
because a detected brownout will reset the chip.
1
BODVDDA_OK
R
RW
0
BOD indicates vdda is ok.
2
BODVCCD_OK
R
RW
1
BOD indicates vccd is ok. This will always read 1,
because a detected brownout will reset the chip.
8
OVDVDDD_OK
R
RW
1
OVD indicates vddd is ok. This will always read 1,
because a detected over-voltage condition will reset
the chip.
9
OVDVDDA_OK
R
RW
0
OVD indicates vdda is ok.
10
OVDVCCD_OK
R
RW
1
OVD indicates vccd is ok. This will always read 1,
because a detected over-over-voltage condition will
reset the chip.
16
OCD_ACT_LINREG_OK
R
RW
1
OCD indicates the current drawn from the linear Active
Regulator is ok. This will always read 1, because a
detected over-current condition will reset the chip.
17
OCD_DPSLP_REG_OK
R
RW
1
OCD indicates the current drawn from the linear
DeepSleep Regulator is ok. This will always read 1,
because a detected over-current condition will reset
the chip.
1651
2022-04-18
TRAVEO™ T2G Automotive MCU: TVII-B-E-4M body controller entry registers