Technical Reference Manual
002-29852 Rev. *B
Bits Name
SW
HW
Default or
Enum
Description
22
WORK_ERR_SILENT
RW
R
0
Specifies bus transfer behavior for a non-recoverable
error on the FLASH macro work interface (either a
non-correctable ECC error, a FLASH macro work
interface internal error, a FLASH macro work interface
memory hole access):
0: Bus transfer has a bus error.
1: Bus transfer does NOT have a bus error; i.e. the
error is 'silent'
In either case, the erroneous FLASH macro data is
returned by the bus master interface. The erroneous
data is NOT placed in a bus master interface's cache
and/or buffer.
This field is ONLY used by CPU (and debug i.e.
SYS_AP/CM0_AP/CM4_AP) bus transfers. Non-CPU
bus transfers always have a bus transfer with a bus
error, in case of a non-recoverable error.
Note: All CPU bus masters have dedicated status
registers (CM0_STATUS and CM4_STATUS) to
register the occurrence of FLASH macro work
interface internal errors (non-correctable ECC errors
and memory hole errors are NOT registered).
Note: fault reporting can be used to identify the error
that occurred:
- FLASH macro work interface internal error.
- FLASH macro work interface non-recoverable ECC
error.
- FLASH macro work interface recoverable ECC error.
- FLASH macro work interface memory hole error.