Technical Reference Manual
002-29852 Rev. *B
16.25.2 HSIOM_MONITOR_CTL_0
Description:
Power/Ground Monitor cell control 0
Address:
0x40302200
Offset:
0x2200
Retention:
Retained
IsDeepSleep:
No
Comment:
This register controls the connectivity of PWR/GND monitor cells to either AMUX bus A or B
respectively.
Default:
0x0
Bit-field Table
Bits
7
6
5
4
3
2
1
0
Name
MONITOR_EN [7:0]
Bits
15
14
13
12
11
10
9
8
Name
MONITOR_EN [15:8]
Bits
23
22
21
20
19
18
17
16
Name
MONITOR_EN [23:16]
Bits
31
30
29
28
27
26
25
24
Name
MONITOR_EN [31:24]
Bit-fields
Bits Name
SW
HW
Default or
Enum
Description
0:31
MONITOR_EN
RW
R
0
control for switch, which connects the power/ground
supply to AMUXBUS_A/B respectively when switch is
closed:
'0': switch open.
'1': switch closed.
1018
2022-04-18
TRAVEO™ T2G Automotive MCU: TVII-B-E-4M body controller entry registers