Technical Reference Manual
002-29852 Rev. *B
Bits Name
SW
HW
Default or
Enum
Description
24:31 STOP_SEL
RW
R
0
Selects one of the 256 input triggers as a stop trigger.
In PWM, PWM_DT and PWM_PR modes, this is the
kill trigger. In these modes, the kill trigger is used to
either temporarily block the PWM outputs
(PWM_STOP_ON_KILL is '0') or stop the functionality
(PWM_STOP_ON_KILL is '1'). For the PWM and
PWM_DT modes, the blocking of the output signals
can be asynchronous (STOP_EDGE should be
NO_EDGE_DET) in which case the blocking is as long
as the trigger is '1' or synchronous (STOP_EDGE
should be RISING_EDGE) in which case it extends till
the next terminal count event.
1812
2022-04-18
TRAVEO™ T2G Automotive MCU: TVII-B-E-4M body controller entry registers