Technical Reference Manual
002-29852 Rev. *B
Bits Name
SW
HW
Default or
Enum
Description
15
RUNNING
R
RW
0
When '0', the counter is NOT running. When '1', the
counter is running.
This field is used to indicate that the counter is running
after a start/reload event and that the counter is
stopped after a stop event.
When a running counter operation is paused in debug
state (see CTRL.DBG_PAUSE) then the RUNNING bit
is still '1'.
16:23 DT_CNT_L
R
RW
0
Generic 8-bit counter field. In PWM_DT mode, this
counter is used for dead time insertion (8bit dead time
counter or low byte of 16-bit dead time counter).
In all other modes, this counter is used for pre-scaling
the selected counter clock. PWM_DT mode can NOT
use prescaled clock functionality.
24:31 DT_CNT_H
R
RW
0
High byte of 16-bit dead time counter. In PWM_DT
mode, this counter is used for dead time insertion.
In all other modes, this field has no effect.
Note: This field only exists when parameter
GRP_AMC_PRESENT for advanced motor control is
set to 1. Otherwise the dead time is only 8bit wide and
the only the field DT_CNT_L is used as dead time
counter.
1797
2022-04-18
TRAVEO™ T2G Automotive MCU: TVII-B-E-4M body controller entry registers