Technical Reference Manual
002-29852 Rev. *B
26.8.46.1.2 CSV_HF_CSV_REF_LIMIT
Description:
Clock Supervision Reference Limits
Address:
0x40261404
Offset:
0x4
Retention:
Retained
IsDeepSleep:
No
Comment:
Default:
0x0
Bit-field Table
Bits
7
6
5
4
3
2
1
0
Name
LOWER [7:0]
Bits
15
14
13
12
11
10
9
8
Name
LOWER [15:8]
Bits
23
22
21
20
19
18
17
16
Name
UPPER [23:16]
Bits
31
30
29
28
27
26
25
24
Name
UPPER [31:24]
Bit-fields
Bits Name
SW
HW
Default or
Enum
Description
0:15
LOWER
RW
R
0
Cycle time lower limit. Set the lower limit -1, in
reference clock cycles, before the next monitored clock
event is allowed to happen. If a monitored clock event
happens before this limit is reached a CSV error is
detected.
LOWER must be at least 1 less than UPPER. In case
the clocks are asynchronous LOWER must be at least
3 less than UPPER.
16:31 UPPER
RW
R
0
Cycle time upper limit. Set the upper limit -1, in
reference clock cycles, before (or same time) the next
monitored clock event must happen. If a monitored
clock event does not happen before this limit is
reached, or does not happen at all (clock loss), a CSV
error is detected.
1693
2022-04-18