EW-601 Instruction for use 

Micro computer humidity controller series 

Code: 601H. 12.08.03

Ewic-601

1. Operating voltage 

AC220V   

10%    50HZ/60HZ

2. Load current 

Alarm relay5A/220V/AC

      Control plus / Dehumidification relay10A/220V/AC

3. Controlled output 

a group control adds/dehumidifies, 

    a group control warning 

4. Control range 

5%RH~95%RH

Does not have the condensation 

5. Power consumption 

:≤

3W

6. Controls the wet precision 

:±

5%      Resolution

:±

1%RH

7. Working environment 

0

℃~

60

    10%

90%RH 

      Does not have the condensation,the standard length 2 m

8. Overall dimension 

76

length

)×

35

wide

)×

76

high

mm

9. Starter size 

71

length

)×

29

wide

mm

EW-601

        First thanks you to use this company measuring appliance 

product. This product union widespread automatic control tech-

nology, the simplicity of operator, controls the warm precision to 

be high, antijamming ability. Applies in equipment's and so on 

air the constant humidity doctor humidity controls and the demo-

nstration (adds wet and dehumidifies dual purpose control model). 

        This product uses the import the humidity sensor, the survey 

humidity is accurate, is stable, and the bringing humidity sensor 

makes a mistake the self-checking function; Dew-point output 

alarm function; Power failure automatic memory function. 

D

Pt

1~20%

0~3

3

0~15

5%

0

H/P

H/P

CA

-10%~10%

0

CP

0~30

6

H

- - this product avoids using easily to have the dew-point situation. 

for example: 1st, airtight, the space small indoor environment (for example cold storage) will 

                         cause the relative humidity to be unusual. 

                       2, thermal shock's environment (for example use forced-air cooling system) will 

                        cause the relative humidity to be unusual. 

Brief on Operation

Demonstration now humidity value

Loud power LED

Technical Specifications

Parameters for Procedure

Function

Indicator

Setting range

Ex-factory 

value

Adds wet/dehumidifies 

Dew point time delay 

The humidity returns to

 the difference 

Delay time 

Humidity Adjustment 

Humidity Delay Change

Unit 

Min

RH

RH

Min

Wiring diagram

/

AP

C/V

C/V

C

S e c

Condensation Way

线

线

线

H

u

m

id

it

y s
e

n

so

1

2

3

1

2

3

6

5

9

11 12

8

Mode

EW-601H

7

10

4

220V/AC

Output Load:
220V/AC

Control 
humidifier 

Warning 
 output 

W

ar

n

in

g

 o

u

tp

u

W

h

ite

B

la

ck

R

ed

5A             10A

A

d

d

s w
et o

ex

si

cc

at

o

13

Отзывы: