Draco tera enterprise
Configuration via Management Software
187
7.5.3 Setting User Macros
In this menu macro commands for switching, disconnection or user administration can be created. Macro
commands are created for each user separately. A macro can execute up to 16 commands successively.
The execution of the macros is done via Hot Key and the F1 to F16 function keys (see chapter 8.1.4,
page 293).
To execute user macros the user has to be logged in to the matrix.
Fig. 119 Management software menu
User Settings - Users & Groups - Users - Macros
The following parameters can be configured:
Field
Selection
Description
Function
(01 to 16)
Connect
(P1=CON, P2=CPU)
Set a bidirectional connection from CON Device P1 to CPU
Device P2
Connect Video
(P1=CON, P2=CPU)
Set a Video Only connection from CON Device P1 to CPU
Device P2
Disconnect
(P1=CON)
Disconnect the CON Device P1
Logout User
Logout the current user
Assign CPU
(P1=VCPU, P2=RCPU)
Assign a virtual CPU Device to a real CPU Device