Draco tera enterprise
Operation via Keyboard
293
8.1.3 Instant Switching via Favorites
Optimal results can be achieved by using identical resolutions as far as possible. This contributes to a
smooth and seamless function of the scan mode.
Switching via favorites enables fast displaying of different video signals by switching between associated
CPU Devices registered as favorites without continuously using the Hot Key.
1. Press the Hot Key to start the command mode.
The Caps Lock and Scroll Lock LEDs on the keyboard are flashing.
2. Press Left Shift and hold it down.
3. Enter the index number of a CPU Devices from the favorites list with the keyboard.
The video signal of the respective source is immediately displayed after entering the index number.
4. Press Esc to leave the instant switching mode.
If you do not enter Esc in between 10 seconds after the last input of an index number, your CON Device will
be switched to the associated CPU Device in Video Only Mode.
8.1.4 Switching via Macros using Function Keys F1 to F16
In the command mode you can retrieve the macros 1 to 32 with the F1 to F16 function keys on the
connected standard keyboard instead of the special macro keyboard.
Executing macros 17 to 32 is realized by the simultaneous use of Left Shift.
The stored command sequence for the appropriate function key is executed and the command mode is left
immediately.
It is not necessary to press Enter to confirm the selection of macros.
8.1.5 Switching a CON Unit to a Local Source
KVM CON Unit extender modules connected to a local source can be locally switched via the matrix.
Switching is performed between the local source and the KVM connection and can be executed via
keyboard commands or OSD (see chapter 9.1.6, page 307).
If you switch to the local source, the KVM connection will be automatically disconnected.
When using CON Units with the possibility to connect a local source in a MSC environment, the local
switching will be disabled.
The following keyboard commands are available to switch to the local source:
Keyboard command
Function
Hot Key, k, 1, Enter
Switch to interconnection port 1.
Hot Key, k, 2, Enter
Switch to interconnection port 2 (only with redundant CON Units).
Hot Key, l, Enter
Switch to the local source.