Configuration via OSD
111
The following functions are available:
Button
Function
New G.
Create a new CPU Group.
Edit
Edit an existing CPU Group.
Delete
Delete an existing CPU Group.
Cancel
Reject changes.
Okay
Apply changes.
The following parameters can be configured:
Field
Entry
Description
ID
Text
Ident number of the CPU Group.
Name
Text
Name of the CPU Group.
Member of Group
Selection
Assign the CPU Device to a CPU Group.
Group
Y
Automatically set if the CPU Device is assigned to a CPU
Group.
N
Function not active (default).
Further parameters are described in chapter 6.6.1, page 108.
To create a CPU Group, proceed as follows:
1. Select
Configuration > CPU Devices
in the main menu.
2. Click
New G.
.
3. Enter a CPU Group name into the field
Name
.
4. Click
Okay
.
The CPU Group is created now.
To assign a CPU Device to a group, proceed as follows:
1. Select
Configuration > CPU Devices
in the main menu.
2. Select the CPU Device you want to assign to a CPU group.
3. Select the CPU Group for the assignment in the field
Member of Group
using the cursor up and down
keys.
4. Click
Okay
.
The CPU Device is assigned to the CPU Group now.