7.8.10 Assigning Virtual CON Devices
In this menu, several real CON Devices can be assigned to a virtual CON Device.
This function reflects changes in permission made to virtual CON Devices onto real CON Devices. Virtual
CON Devices can be switched in the same way as real CON Devices. Real CON Devices that are assigned
to a virtual CON Device that is connected to a CPU Device will receive the video signal. The last assigned
CON Device will also have control of the keyboard and mouse.
A virtual CON Device can be assigned to more than one real CON Devices.
NOTICE
If the
Auto Send
checkbox is ticked in the lower left corner of the workspace, the switching operations
will be performed immediately without user confirmation by clicking
Send
.
Fig. 175 Management software menu
Assignment - Virtual CON Devices
The following functions are available:
Button
Function
Send
Send assignments to the matrix
Reload
Reload changes
The selection boxes in the
Virtual CON Device
column contain a filter function for an easy selection of a
single CON Device from a larger pool of CON Devices.