Configuration via Management Software
261
Configuring Multi-Head sources for Multi-Screen Control
NOTICE
A Multi-Head configuration for Apple Mac sources is not supported due to limitations of the macOS.
For the use of Multi-Head sources, an additional configuration of the CPU Devices is mandatory. The
configuration of CPU Devices, which are connected to Single-Head sources is not mandatory.
Fig. 177 Management software menu
Extender & Devices - CPU Devices - Monitor Arrangement
For an additional configuration of the CPU Devices for the use of Multi-Head sources, proceed as follows.
1. Click
Extender & Devices > CPU Devices
in the task area.
2. Click
Activate Edit Mode
in the toolbar.
3. Select the CPU Device to be configured.
4. Click the
Monitor Arrangement
tab.
5. Enter the resolution of the total desktop area into the fields
Total Desktop Resolution
. For instance, if
there are 4 graphic card outputs with a resolution of 1920x1080 each, you have to enter 7680 under
Width
and 1080 under
Height
.
6. Select the individual resolution of the graphic card output from the selection list in the field
Resolution 1
(e.g., 1920x1080). This is the graphic card output the CPU Device is connected to.
7. Enter the respective pixel coordinates that particular screen in the MSC arrangement into the fields
Offset X
and
Offset Y
.
Note:
Offset: X=0/Y=0 defines the upper left corner.
For instance, you have to enter 1920 for a shift of 1920 pixels to the right into the field Offset X.
The corresponding screen will be positioned accordingly within the light blue grid.