![Ihse Draco tera enterprise 480 Series Скачать руководство пользователя страница 298](http://html.mh-extra.com/html/ihse/draco-tera-enterprise-480-series/draco-tera-enterprise-480-series_user-manual_623699298.webp)
Operation via Keyboard
Draco tera enterprise
298
8.4 Overview of Keyboard Commands
In the following you find a summary of keyboard commands that can be used to configure and activate
extender module and matrix functions.
8.4.1 Extender Module
8.4.1.1 Keyboard Commands for Configuration
Keyboard command
Function
Hot Key, c, new
Hot Key code, Enter
Change the Hot Key according to the predefined Hot Key Code table.
Hot Key, c, 0, new
Hot Key, Enter
Define a freely selectable Hot Key.
Right Shift + Del within
5 s after switching on
the CON Unit or
plugging in a keyboard
Reset the Hot Key back to default settings.
Hot Key, f, Hot Key
Code, Enter
Define a Fast Key according to the predefined Hot Key Code table to open the
OSD directly.
Hot Key, f, o, new
Hot Key, Enter
Define a freely selectable Fast Key to open the OSD directly.
Hot Key, f, 0, Del, Enter Delete the Fast Key.
8.4.1.2 Keyboard Commands for Operation
Keyboard command
Function
Hot Key, a
Download the EDID of a monitor connected to the CON Unit into the CPU Unit.
Hot Key, h, w, Enter
Write the device descriptions of the input devices connected to the CON Unit
into the CPU Unit. Activate the emulation of these device descriptions in the
CPU Unit.
Hot Key, h, e, Enter
Activate the emulation of already stored device descriptions in the CPU Unit.
Hot Key, h, d, Enter
Deactivate the emulation of active device descriptions in the CPU Unit. The
input devices connected to the CON Unit will be now passed transparently to the
source.
Hot Key, h, r, Enter
Deactivate the emulation of active device descriptions in the CPU Unit. Deletes
the descriptions out of the CPU Unit. The input devices connected to the
CON Unit will be now passed transparently to the source.
Hot Key, k, 1, Enter
Switch to the extender module interconnection port 1.
Hot Key, k, 2, Enter
Switch to the extender module interconnection port 2.
Hot Key, l, Enter
Switch to local source (only CON Units with port for a local input).
Hot Key, d, 1, Enter
Switch to video channel 1 of a Dual-Head CPU Unit.
Hot Key, d, 2, Enter
Switch to video channel 2 of a Dual-Head CPU Unit.
Содержание Draco tera enterprise 480 Series
Страница 141: ...Draco tera enterprise Configuration via OSD 141 Fig 93 Menu Configuration System ...
Страница 360: ...Maintenance Draco tera enterprise 360 Fig 265 Management software report Network Check Available ports ...
Страница 374: ...Maintenance Draco tera enterprise 374 Fig 282 Management software Flash Update Firmware Check Complete firmware update ...