![Ihse Draco tera enterprise 480 Series Скачать руководство пользователя страница 210](http://html.mh-extra.com/html/ihse/draco-tera-enterprise-480-series/draco-tera-enterprise-480-series_user-manual_623699210.webp)
Configuration via Management Software
Draco tera enterprise
210
7.6.6 Configuring EXT Units for USB 3.0/USB 2.0 Extender Modules
To use USB 3.0/USB 2.0 extender modules connected to a UNI I/O board, SFP modules based on
6.25 Gbit/s are required. The configuration of EXT Units for USB 2.0/USB 3.0 extender modules is set in
this menu.
USB 2.0 extender modules can also be used with UNI I/O boards and SFP modules based on 6.25 Gbit/s
or can be connected to fixed ports of I/O boards (see chapter 7.6.5, page 208).
Fig. 141 Management software menu
Extender & Devices - EXT Units - Expert View - Extender Type
To configure an SFP for using with USB 2.0/USB 3.0 extender modules, proceed as follows:
1. Select
Configuration > EXT Units
in the main menu.
2. Insert the SFP modules into the matrix and connect the extender module according to the required
application.
One EXT UNIT will be created for each SFP module in the
EXT Units
list. The appropriate names
always start with “UNI”.
3. To configure an EXT Unit as a CON Unit:
3.1. Select one of the EXT Units in the
EXT Units
list that are physically connected to a USB
CON Unit.
3.2. Select the item
UNI CON USB
in the
Type
selection box of the
Extender Type
tab.
3.3. Click
Apply
to confirm the setting.
3.4. Click
Yes
to restart the I/O board upon request in the dialog.
Содержание Draco tera enterprise 480 Series
Страница 141: ...Draco tera enterprise Configuration via OSD 141 Fig 93 Menu Configuration System ...
Страница 360: ...Maintenance Draco tera enterprise 360 Fig 265 Management software report Network Check Available ports ...
Страница 374: ...Maintenance Draco tera enterprise 374 Fig 282 Management software Flash Update Firmware Check Complete firmware update ...