![Ihse Draco tera enterprise 480 Series Скачать руководство пользователя страница 84](http://html.mh-extra.com/html/ihse/draco-tera-enterprise-480-series/draco-tera-enterprise-480-series_user-manual_623699084.webp)
Configuration via OSD
Draco tera enterprise
84
Log Levels
Field
Entry
Description
Trace
DEB
Activate debug messages in trace (default: N).
Note:
The debug messages are exclusively for matrix
diagnostics. They only should be activated after consultation
with the manufacturer. Otherwise, an increased traffic of data
might limit the performance of the controller board.
INF
Activate information messages in trace (default: N).
NOT
Activate notification messages in trace (default: Y).
WAR
Activate warning messages in trace (default: Y).
ERR
Activate error messages in trace (default: Y).
Syslog #1/#2
DEB
Activate debug messages in Syslog (default: N).
Note:
The debug messages are exclusively for matrix
diagnostics. They only should be activated after consultation
with the manufacturer. Otherwise, an increased traffic of data
might limit the performance of the controller board.
INF
Activate information messages in Syslog (default: N).
NOT
Activate notification messages in Syslog (default: Y).
WAR
Activate warning messages in Syslog (default: Y).
ERR
Activate error messages in Syslog (default: Y).
To set parameters for the network configuration, proceed as follows:
1. Select
Configuration > Network
in the task area.
2. Change the desired settings.
3. Click
Okay
to confirm your entries.