![Ihse Draco tera enterprise 480 Series Скачать руководство пользователя страница 212](http://html.mh-extra.com/html/ihse/draco-tera-enterprise-480-series/draco-tera-enterprise-480-series_user-manual_623699212.webp)
Configuration via Management Software
Draco tera enterprise
212
7.6.7 Configuring EXT Units for SDI Usage
For the use of SDI, the matrix is to be configured in this menu. Using SDI requires at least one UNI I/O
board and appropriate SFP modules according to the SDI video signal to be used.
Fig. 142 Management software menu
Extender & Devices - EXT Units - Expert View - Extender Type
To configure an SFP for using as an SDI input/output, proceed as follows:
1. Select
Configuration > EXT Units
in the main menu.
2. Insert the SFP modules into the matrix and connect the extender module according to the required
application.
One EXT UNIT will be created for each SFP module in the
EXT Units
list. The appropriate names
always start with “UNI”.
3. To configure an EXT Unit as an SDI input:
3.1. Select one of the extender modules in the
EXT Units
list that are physically connected to a USB
CON Unit.
3.2. Select the
UNI CPU
item in the
Type
selection box of the
Extender Type
tab.
3.3. Click
Apply
to confirm the setting.
3.4. Click
Yes
to restart the I/O board upon request in the dialog.