![Ihse Draco tera enterprise 480 Series Скачать руководство пользователя страница 325](http://html.mh-extra.com/html/ihse/draco-tera-enterprise-480-series/draco-tera-enterprise-480-series_user-manual_623699325.webp)
Draco tera enterprise
Maintenance
325
13.1.1.3 Opening and Uploading the Backup Data
Preconditions
•
The computer running the management software is connected to the matrix via TCP/IP port.
•
The management software is running.
•
The matrix is connected via management software.
Opening a locally saved Backup File
To load a locally saved backup file, please see chapter 7.14.2, page 289.
Uploading a Configuration
To upload an opened locally saved backup file, please see chapter 7.14.3, page 289.
13.1.2 Replacing a Controller Board
NOTICE
Damaged controller board due to by switching off the matrix during replacement process
When replacing a controller board, the new one will automatically receive the current matrix configuration.
Therefore, it is necessary to perform a correct de-registration of the controller board to be replaced and a
correct registration of the new controller board. Switching off the matrix during the replacement process
may cause a disfunction or a damage of the controller board.
Observe the steps described in this chapter.
Wait until the old board has been de-registered and the new board has been registered.
Do NOT switch off the matrix while replacing the controller board replacement.
Fig. 232 Interface side - Draco tera controller board 480-CTRL2
1 Controller board status LED 1
2 Controller board status LED 2
3 Locking pin
To replace a controller board, proceed as follows:
1. Pull the locking pin slowly out of the controller board up to the stop.
Wait until the LED 1 illuminates solid green and the LED 2 flashes red (de-registration confirmed, see
2. Remove all cables from the controller board.
3. Pull the controller board out of the corresponding slot by using the locking pin.
4. Push a new or maintained controller board into the slot.
5. Push the locking pin completely in.
A successful registration of the controller board will be shown by a permanent green flashing of status
LED 1.
6. Connect all cables to the controller board according to the replaced board.