1.
Make sure that there are no obstructions, such as
bundled cables, to the airflow from the power-supply
fan.
2.
Replace power supply n. (n = power supply
number)
80070208-0a01ffff
Sensor [SensorElementName]
has transitioned to critical from a less
severe state. (PS 1 Therm Fault)
Explanation:
This message is for the use case when
an implementation has detected a Sensor transitioned
to critical from less severe.
Internal Event:
No
Severity:
Error
Alert Category:
Critical - Power
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0522
SNMP Trap ID:
4
Automatically notify Support:
No
User response:
1.
Make sure that there are no obstructions, such as
bundled cables, to the airflow from the power-supply
fan.
2.
Use the IBM Power Configurator utility to ensure
current system power consumption is under
limitation. For more information and to download the
utility, go to http://www-03.ibm.com/systems/
bladecenter/resources/powerconfig.html.
3.
Replace power supply n. (n = power supply
number)
80070208-0a02ffff
Sensor [SensorElementName]
has transitioned to critical from a less
severe state. (PS 2 Therm Fault)
Explanation:
This message is for the use case when
an implementation has detected a Sensor transitioned
to critical from less severe.
Internal Event:
No
Severity:
Error
Alert Category:
Critical - Power
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0522
SNMP Trap ID:
4
Automatically notify Support:
No
User response:
1.
Make sure that there are no obstructions, such as
bundled cables, to the airflow from the power-supply
fan.
2.
Use the IBM Power Configurator utility to ensure
current system power consumption is under
limitation. For more information and to download the
utility, go to http://www-03.ibm.com/systems/
bladecenter/resources/powerconfig.html.
3.
Replace power supply n. (n = power supply
number)
8007020f-2201ffff
Sensor [SensorElementName]
has transitioned to critical from a less
severe state. (TXT ACM Module)
Explanation:
This message is for the use case when
an implementation has detected a Sensor transitioned
to critical from less severe.
Internal Event:
No
Severity:
Error
Alert Category:
Critical - Other
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0522
SNMP Trap ID:
50
Automatically notify Support:
No
User response:
1.
If enabling TXT is not required, disable TXT from
the Setup Utility.
2.
If enabling TXT is required, verify that the TPM is
enabled and activated from the Setup Utility.
3.
If the problem remains, contact your service
representative.
8007020f-2582ffff
Sensor [SensorElementName]
has transitioned to critical from a less
severe state. (I/O Resources)
Explanation:
This message is for the use case when
an implementation has detected a Sensor transitioned
to critical from less severe.
Internal Event:
No
Severity:
Error
Alert Category:
Critical - Other
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0522
SNMP Trap ID:
50
Automatically notify Support:
No
User response:
Complete the following step to solve
PCI I/O resource errors:
1.
Go to F1 Setup
2.
System Settings
3.
Device and I/O ports
4.
PCI 64 bit Resource and choose enable.
80070208-0a01ffff • 8007020f-2582ffff
Chapter 3. Diagnostics
67
Содержание System x iDataPlex dx360 M4 7912
Страница 1: ...System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Страница 22: ...4 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Страница 278: ...260 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Страница 292: ...274 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Страница 392: ...374 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Страница 399: ......
Страница 400: ...Part Number 46W8218 Printed in USA 1P P N 46W8218...