2. If a GPGPU enclosure is installed on the system-board tray, remove it (see
“Removing a GPGPU enclosure” on page 281).
3. Carefully set the GPGPU enclosure on a flat, static-protective surface.
4. Remove the hard disk drive filler or the simple-swap hard disk drives, if any is
installed (see “Removing a simple-swap hard disk drive” on page 293). Place
them on a static-protective surface.
5. Remove the simple-swap SAS/SATA drive cage (see “Removing a simple-swap
SAS/SATA drive cage” on page 299).
6. Remove retention pin and bracket.
7. Remove the PCIe adapters, if any are installed (see “Removing a PCIe adapter
from a PCI riser-card assembly” on page 304).
8. If you are instructed to return the GPGPU enclosure, follow all packaging
instructions, and use any packaging materials for shipping that are supplied to
you.
Installing a GPGPU enclosure
To install a GPGPU enclosure, complete the following steps.
Retention bracket
Retention pin
Adapter
3.5-inch
simple-swap
backplate
3.5-inch
simple-swap
hard disk drive
3.5-inch
filler panel
GPGPU enclosure
1. Install the PCIe adapters, if you removed any (see “Installing an adapter in the
GPGPU enclosure (PCI slot 3 or slot 4)” on page 306 and “Installing an adapter
in the GPGPU enclosure (PCI slot 1 or slot 2)” on page 308).
2. Install retention pin and bracket.
3. Install the simple-swap SAS/SATA drive cage (see “Installing a simple-swap
SAS/SATA drive cage” on page 300).
4. Install the hard disk drives, if you removed any (see “Installing a simple-swap
hard disk drive” on page 294).
5. Install the GPGPU enclosure on the system-board tray (see “Installing a
GPGPU enclosure” on page 282).
Removing and replacing Tier 2 CRUs
You may install a Tier 2 CRU yourself or request IBM to install it, at no additional
charge, under the type of warranty service that is designated for your server.
The illustrations in this document might differ slightly from your hardware.
324
System x iDataPlex dx360 M4 Types 7912 and 7913: Problem Determination and Service Guide
Содержание System x iDataPlex dx360 M4 7912
Страница 1: ...System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Страница 22: ...4 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Страница 278: ...260 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Страница 292: ...274 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Страница 392: ...374 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Страница 399: ......
Страница 400: ...Part Number 46W8218 Printed in USA 1P P N 46W8218...